Specifications |
Model:
|
ADMM 4 Pro HS |
ADMM 8 Pro |
Inputs:
|
4
|
8
|
Measurement Ranges: |
±10 mV, ±20 mV, ±50 mV,
±100 mV, ±500 mV,
±1 V, ±2 V, ±5 V, ±10 V, ±20 V, ±60 V |
Internal Sampling Rate
per Channel |
10 kHz |
2 kHz |
Measurement Data Rate per Channel |
1, 2, 5, 10, 50, 100, 500 Hz,
1 kHz, 2 kHz, 5 kHz, 10 kHz |
1, 2, 5, 10, 50, 100, 500 Hz,
1 kHz, 2 kHz |
Input Protection |
±100 V permanent,
additional ESD protection |
SW Input Filter |
Selectable 6th order Butterworth,
range 0.1 Hz to 2 kHz |
Selectable 6th order Butterworth,
range 0.1 Hz to 500Hz |
HW Input Filter |
Low-pass filter 3rd order, approx. 2 kHz |
Low-pass filter 3rd order, approx. 500 Hz |
Sensor Excitation |
±5 V, ±8 V, ±10 V, ±12 V,
±15 V DC |
|
Per channel typ. ±60 mA,
max. ±120 mA |
Per channel typ. ±30 mA,
max. ±120 mA |
|
Selectable and adjustable
per channel |
Accuracy at 25 °C
Temperature Drift |
0.05 %
Typ. ±10 ppm/K |
Galvanic Isolation |
500 V DC |
CAN Interface
Configuration |
CAN2.0B (active), High
Speed (ISO 11898)
125 kBit/s up to max. 1 MBit/s, data transfer is free
running
Via CAN bus with CSM Config Tool or CSM INCA AddOn,
All settings and configuration data are stored within module |
Sampling Points |
32 points |
2 points |
Power Supply |
Approx. 5 V to 60 V
DC |
Power Consumption |
Typ. 1.5 to 2.3 W
(without sensor excitation) |
typ. 1.8 W
(without sensor excitation) |
Dimensions (W x H x D) |
120 x 37 x 50 mm
(Slide Case) |
200 x 40 x 50 mm
(Slide Case) |
Weight |
Approx. 300 |
Approx. 500 g |
Protection Class |
IP67 |