Specifications |
Inputs |
8
|
Measurement ranges |
±10, ±20, ±50, ±100, ±200, ±500mV and ±1, ±2, ±5, ±10 ±20, ±60
V |
Internal resolution |
16 bit |
Internal sampling rate per Channel
|
2 kHz
|
Measurement data range per channel
|
1, 2, 5, 10, 50, 100, 500 Hz and 1 kHz, 2 kHz
|
Input Protection
|
±100 V permanent, additional ESD protection
|
SW input filter
|
Selectable 6th order Butterworth filter, range: 0.1 Hz to 500
Hz
Automatically adjusted to measurement data rate,
alternatively: threshold frequency adjustable per channel |
HW input filter
|
Low-pass filter 3rd order, approx. 500 Hz |
Sensor Excitation
|
±5, ±8, ±10, ±12, ±15 V DC per channel typ. ±30 mA, selectable
and adjustable per channel |
Accuracy at 25 °C
Temperature Drift
|
0.05 %
Typ. ±10 ppm/K |
Galvanic Isolation
|
500 V DC |
CAN Interface
Configuration
|
CAN2.0B (active), High Speed (ISO 11898)
125 kBit/s up to max. 1 MBit/s, data transfer is free
running
Via CAN bus with CSM Config Tool or CSM INCA AddOn,
All settings and configuration data are stored within module |
Sockets:
CAN / power supply
Signal inputs / sensor excitation
|
LEMO 0B 5-pole
LEMO 0B 6-pole |
Power Supply
|
Approx. 6 V to 50 V DC
|
Power Consumption
|
1.8W (without sensor excitation)
|
Operating temperature |
-40 ° C to +125 ° C |
Dimensions |
200 x 40 x 50mm
(Slide Case) |
Weight |
500 g |
Protection Class |
IP67
|